DISTRIBUTION SYSTEMS - ELECTRICA L POWE R SYSTEM
Battery - General specication (A.30.A.83 - D.40.A.10)
435, 445, 445CT
Charging Guide For Maintenance Free Batteries - Recommended Rate* and Time for Fully Discharged
Battery
Battery Capacity - See Reserve Capacity under
Specications
Charge
80 Minutes or Less 10 Hou rs at 5 Amperes
5 Hours at 10 Amperes
Above 80 t o 125 Minutes 15 Hours at 5 Amperes
7.5 Hours at 10 Amperes
Above 125 to 170 Minutes 20 Hours at 5 Amperes
10 Hours at 10 Amperes
Above 170 to 250 Minutes 30 Hours at 5 Amperes
15 Hours at 10 Amperes
*Initial rate for standard taper charger.
NOTE: A maintenance free battery will have the words Maintenance Free on the decal on the top of the battery. If
the center part of the decal has been removed to get access to the battery caps, it is possible the words Maintenance
Free will have been removed from the decal.
Charging Guide For Batteries Other Than Maintenance Free Batteries - Recommended Rate* and Time
for Fully Discharged Battery
Battery Capacity - See Reserve Capacity under
Specications
Charge
80 Minutes or Less 10 Hou rs at 5 Amperes
5 Hours at 10 Amperes
Above 80 t o 125 Minutes 15 Hours at 5 Amperes
7.5 Hours at 10 Amperes
Above 125 to 170 Minutes 20 Hours at 5 Amperes
10 Hours at 10 Amperes
Above 170 to 250 Minutes 30 Hours at 5 Amperes
15 Hours at 10 Amperes
Above 250 Minutes 24 Hours at 10 Amperes
*Initial rate for standard taper charger.
1 04/05/2005