[ 26 ] Drawer open test
[Function]
This test will check the drawer open function.
[Operation]
Operation : x n 0 9 1 SUBTOTAL
x : 0 = All drawers open (can be omitted)
1 = Drawer 1 open
n : 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press “C” key or turn off the power by rotating
the key.)
* Drawer status data is displayed in the transaction status display unit.
Status condition is displayed after all drawers open while performing continuous check.
[Print]
DRW 9 1
DRW AL L OK
END 91
DRW 10091
DRW 1 OK
END 10091
x=0 x=1
[ 27 ] Buzzer test
[Function]
This test will check the buzzer function.
Ring the one-shot buzzer.
Ring the 500msec intermittent buzzer while performing continuous check.
Press “C” key or turn off the power to stop the intermittent buzzer.
[Operation]
Operation : n 0 9 2 SUBTOTAL
n : 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press “C” key or turn off the power by rotating
the key.)
[Print]
BUZZ 92
END 92