- 45 -
[PRINT] [DISPLAY]
Normal End
Error End (Time out error)
Segment display
Count data block
Error List
ARCNET BLK ERR 10 0001 ------ Block No. is not same No. between send and
reception.
ARCNET DATA ERR 20 0001 ------ Data is not same between send and reception.
ARCNET LENG ERR 40 0001 ------ Data Length is not same between sand and
reception.
ARCNET TIMEOUT 80 0001 ------ Time out error during communication time or
starting time.
ARCNET OPEN ERR xx 0001 ------ Failuer of ARCNET initialization.
xx: 01= Chip error, register data is not stable.
04= ARCNET chip not exist.
05= Failuer of reset operation
06= Status RI is not changed to 1 after
accept of reception.
07= Diagnostic operation failuer. After
initialize the chip, chip RAM's first
address data is not D1h.
08= Duplicate ID error
14= Power down error
Error code
Error conter