KEQS08
KEQS08-R_211221_VXX02_GB
Single-phase control unit for 1 motor 230Vac
For sliding gates or swing gate with 1 motor, roll-up doors, rolling shutters with
electrical lock and encoder option
433.92 Radio receiver integrated with obstacle detection
Radio receiver
-1-
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-9-
-10-
-11-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
230 Vac
230 Vac
Lamp
Lamp
MOT common
MOT close
MOT open
+ Antenna Signal
Common contacts
Common contacts
+ 12 Vdc
STOP
PHOTO 1
LSO
LSC
START
PEDESTRIAN
24 Vac
24 Vac / + 24Vdc
M
OP
CL
COM
OUT
TX
-22-
-23-
Electrical lock
12 Vac
-24-
-25-
Dry Contact
Dry Contact
N.C.
Photocells working
in closing
See par. 2.10-2.11
Lamp or courtesy light
230Vac
C
100%
ITALY
N.C.
N.C.
N.O N.O.
RX
-20-
-21-
-24Vdc, COM serv. & sec.
PHOTO 2
-26-
-28-
+ 5V encoder
- 5V encoder
-27-
Encoder Signal
12 Vac Electrical lock
(in case of 24Vac connect to the terminal
board no.22 and 18)
For a correct use of the encoder,
we recommend to ready the manual.
!
Radio receiver
OUT
TX
Photocell working in closing
and in opening
RX
Question and Answer IconNeed help?

Do you have a question about the Casit KEQS08 and is the answer not in the manual?

Summary

Foreword

Environmental protection measures

Symbols and warning

DANGEROUS

Warning about potential material damage if not respected.

DEVICE UNDER TENSION

Installation should only be done by a professional installer.

READ CAREFULLY THE OPERATING MANUAL

Read manual before installation and keep for future reference.

1 Introduction

1.1 Safety precautions

Improper use voids warranty; producer declines responsibility for damages.

1.2 Field of application

Control unit for automatic gates, swinging gateways, rolling gates, automatic doors.

1.3 Type of installation

Diagrams show application examples for sliding and swing gates.

1.4 Technical description

Table listing dimensions, weight, and power specifications.

2 Installation

2.1 Diagram of the control unit and electrical connections

Visual guide to control unit terminal connections and power supply.

Connection of the POWER SUPPLY LINE

Power supply line requires protection with a magnetic-thermal switch or fuses.

Connection of the MOTOR

Caution on pole inversion and correctly connecting motor OPEN/CLOSE wires.

2.2 Description of the electrical connection

Detailed table listing terminal numbers and their respective functions.

2.3 Connection of the 230 Vac SIGNAL LIGHT

Wiring for signal light with or without flashing control card.

2.4 Connection of one 24 V LIGHT for open or moving gate

Wiring diagram for a 24V light used for gate opening or movement.

2.5 Connection of the COURTESY light

Wiring diagram for connecting a 230Vac courtesy light.

2.6 Power supply of the ACCESSORIES

Details on connecting 12 Vdc and 24 Vdc/Vac accessories.

2.7 Connection of the STOP and PHOTO 2

Instructions for connecting STOP button and PHOTO 2 photocell.

2.8 Connection of LIMIT SWITCHES LSO and LSC

Wiring for LSO and LSC limit switches, noting they use NC contacts.

2.9 Connection of the MAGNETIC LIMIT SWITCHES

Wiring for magnetic limit switches using 24 Vdc power.

2.10 Connection of the 24 Vac photocell 1 only closing

Diagrams for connecting a 24 Vac photocell with and without TEST function.

2.11 Connection of the 24 Vdc photocell 1

Diagrams for connecting a 24 Vdc photocell with and without TEST function.

2.12 Connect the 3 WIRES PHOTO 1 24 Vdc

Wiring diagram for a 3-wire 24 Vdc photocell.

2.13 Electrical lock connection: 12 or 24 Vac

Wiring diagrams for 12 Vac and 24 Vac electrical locks.

2.14 Connection of the START and PEDESTRIAN commands

How to connect START and PEDESTRIAN commands, including timer use.

2.15 Checking connections

How to check connections using LEDs and indicator lights.

3 Functions and adjustments of DIP SWITCHES

3.1 Use of the DIP B

Explains functions of DIP B switches 1-8 for various inputs and modes.

3.2 Use of the DIP A

Detailed explanation of DIP A switches 1-10 for operational modes like Automatic, Condominium, Semi-automatic.

3.3 JP1 function: “Death man” function

Describes the safety function of the JP1 jumper.

4 Using the remote controls

4.1 FULL CANCELLATION of the memory

Procedure to erase all remote control codes from memory.

4.2 ROLLING CODE ACTIVATION OR DEACTIVATION

Instructions to switch between fixed code and rolling code modes.

4.3 Learning of the remote controls

Step-by-step guide to program new remote controls.

5 Reset of the memory at factory settings

6 Time learning

6.1 Time learning: STANDARD WAY

Guide for learning standard opening and closing times.

6.2 Time learning PARTIAL OPENING

Procedure to learn the time for partial gate opening.

6.3 Time learning: pause (easy way)

Simple method to set the pause time for the gate.

6.4 Time learning: ADVANCED SYSTEM

Advanced method for learning motor running and slowing down times.

7 OPERATING GUIDE FOR TEST

8 Adjustment of the Trimmers

8 Declaration of CE conformity

Overview

The KEQS08 is a single-phase control unit designed for various automated gate and door systems, including sliding gates, swing gates, roll-up doors, and rolling shutters, especially those equipped with an electrical lock and an encoder option. It operates on a 230Vac power supply and features an integrated 433.92 MHz radio receiver with obstacle detection capabilities.

Function Description:

The control unit manages the movement of an asynchronous, single-phase motor operating at 230Vac. It supports various operational modes, including automatic, semi-automatic, and condominium modes, which dictate how the gate responds to commands and handles automatic closing. The system incorporates safety features such as inputs for STOP buttons, photocells (PHOTO 1 and PHOTO 2), and limit switches (LSO and LSC) to prevent accidents and ensure safe operation. An encoder input allows for precise control of motor movement and obstacle detection. The unit also provides outputs for a 230Vac signal light or courtesy light, and power supplies for various accessories (12Vdc, 24Vac/dc). An electrical lock can be integrated, with options for 12Vac or 24Vac operation.

Important Technical Specifications:

  • Dimensions: 87 x 150 x 45 mm
  • Weight: 0.6 Kg
  • Control Unit Power Supply: 230Vac 50 Hz
  • Motor Power Supply: 230Vac
  • Max Power of Single Motor: 1 HP (750 W, 4 A)
  • Max Power of Signal Light 230 Vac: 40 W
  • Max Consumption for Dry Contacts: 2 A
  • Max Consumption 24 Vac/dc: 300 mA
  • Max Consumption 12 Vdc: 50 mA
  • Max Consumption 12 Vac: 1 A
  • Radio Receiver: Integrated 433.92 MHz, manages standard codes (12 to 64 bit) and HCS© rolling codes.

Usage Features:

Electrical Connections:

The control unit has clearly defined terminals for various connections:

  • Power Supply (1-2): 230Vac 50 Hz for the control unit.
  • Motor and Signal Light (3-7): 230Vac for motor common, closing, opening poles, and signal/courtesy light (max 40W).
  • Accessories and Inputs (8-21):
    • Antenna signal (8).
    • Common for all inputs (9-10).
    • +12Vdc output (11) for accessories (max 50mA).
    • STOP input (12).
    • PHOTO 1 input (13) for closing intervention only.
    • LSO (14) and LSC (15) inputs for opening and closing limit switches.
    • START (16) and PEDESTRIAN (17) inputs for bistable commands.
    • 24Vac (18), +24Vdc/24Vac (19), -24Vdc (20) outputs for accessories (max 300mA).
    • PHOTO 2 input (21) for opening and closing intervention (DIP6A).
  • Electrical Lock (22-23): 0Vac and 12Vac outputs for electrical lock. For 24Vac locks, connect to terminals 22 and 18 with the AC/DC jumper set to AC.
  • Dry Contacts (24-25): For light or photocell TEST, or flashing light without intermittence circuit board.
  • Encoder (26-28): +5Vdc, Signal, and -5Vdc for encoder power and signal.

DIP Switch Settings (DIP A and DIP B):

DIP switches allow customization of the control unit's logic and input exclusions.

  • DIP B (Functions and Adjustments):
    • 1-ON: Excludes STOP input (12).
    • 2-ON: Excludes PHOTO 1 input (13).
    • 3-ON: Excludes LSO input (14).
    • 4-ON: Excludes LSC input (15).
    • 5-ON: Excludes PHOTO 2 input (21) (Safety edge 8K2).
    • 6-ON: Activates Soft-Start (gradual opening speed).
    • 7-ON: Industrial use (Partial Opening becomes CLOSE, START becomes OPEN, automatic closing based on DIP1A/DIP2A settings).
    • 8-ON: Not used.
  • DIP A (Logic of the Control Unit):
    • 1-OFF, 2-OFF: Automatic 1 (inverts open/close, auto-closes after pause time).
    • 1-ON, 2-OFF: Condominium (no commands during open/pause, auto-closes after pause time).
    • 1-OFF, 2-ON: Semi-automatic (open-stop-close-stop-open, no auto-closing).
    • 1-ON, 2-ON: Automatic 2 (open-stop-close-stop-open, auto-closes after pause time).
    • 3-ON: Reversing Stroke (allows electrical lock release).
    • 4-ON: Courtesy light (terminals 3 and 4 powered during opening and up to 2 min after closing).
    • 5-ON: Pre-lighting (ON: 4 seconds pre-lighting; OFF: deactivated).
    • 6: Photo 2 (ON: stops and reverses motion for 2s after 1 min, then closes again; OFF: stops and reopens with obstacle removed, re-closes after pause time).
    • 7: Motor starting 3 sec after LSC (ON: motor runs for 3s; OFF: motor runs until LSC activation).
    • 8-ON: Phototest (activates TEST in PHOTO, STOP, SAFETY EDGE inputs).
    • 9-ON: Logic of obstacle detection (A) (reverses direction up to FCA, pauses 1 min, then closes again; new START command reopens).
    • 9-OFF: Logic of obstacle detection (B) (works as limit switch).
    • 10-ON: Programming time, advanced system (activates advanced working time).

JP1 Function:

  • JP1 close: "Death man" function (START opens, PARTIAL OPENING closes; motors stop immediately when button is released).

Remote Control Management:

The receiver supports 12-64 bit standard codes and HCS© rolling codes. The first learned transmitter determines the code type.

  • Full Cancellation of Memory: Press and hold CODICI button until LED L1 flashes, then release. Gate must be closed.
  • Rolling Code Activation/Deactivation:
    • Fixed code mode (L1 - one flash): Press and release CODICI, L1 lights up.
    • Rolling code mode (L1 - flashes twice): Press and release CODICI, L1 flashes and lights up. Press CODICI again, L1 flashes twice to activate rolling code counter.
  • Learning Remote Controls: Gate must be closed. Press and release CODICI (L1 lights up). Press the remote control button (L1 flashes if memorized). For partial opening, repeat with a different remote button.

Working Time Learning:

  • Standard Way: Set semi-automatic mode (DIP 1A OFF, DIP 2A ON, DIP 7B OFF). Put DIP 10A OFF. Press TEMPI (motor opens). Wait for first leaf to open (or press TEMPI to stop). Wait for desired pause time. Press TEMPI (motor closes). Wait for gate to close.
  • Partial Opening: Press and hold TEMPI until motor opens, then release. Press TEMPI (motor stops). Let pause time run. Press TEMPI (motor closes). Wait for gate to close (or until limit switch stops motor).
  • Pause (Easy Way): Press and release TEMPI (L.E.D. lights for opening/closing are LIT ON). Let new pause time run. Press TEMPI (gate closes, time learning completed).
  • Advanced System: Put DIP 10A ON. Press TEMPI (motor opens). Press TEMPI (motor opens slowly if slowing down activated). Press TEMPI (motor stops, pause time starts). Wait until motor stops (if limit switch available). Let pause time run. Press TEMPI (motor closes). Press TEMPI (motor closes slowly if slowing down activated). Press TEMPI (motor stops, advanced learning completed).

Adjustment of Trimmers:

  • FORZA (Force): Adjusts motor force from 20% to 100%.
  • V.RALL (Speed of Slowing Down): Adjusts slowing down speed (MINIMUM OFF deactivates). Best value is MIN to 4. To deactivate, turn trimmer to OFF.
  • BLOCK (Obstacle Detection): Adjusts force needed to stop motor. MIN requires little force, turning up requires more force. OFF deactivates the function.

Maintenance Features:

  • Checking Connections: LED L1 flashes each second to indicate correct working. Soft flashing indicates SAFETY EDGE input is not in standard mode. Red lights on inputs STOP, PHOTO, LSO, LSC are ON when contacts are closed. Green lights on START, PEDESTRIAN are OFF.
  • Reset of Memory at Factory Settings: Press CODICI and TEMPI buttons simultaneously (L1 lights ON). Wait 10 seconds until L1 switches OFF. Release buttons. This resets all parameters but does not cancel remote control codes.
  • Environmental Protection: The device should be disposed of separately from undifferentiated urban waste, following local regulations for electronic equipment recycling.

Safety Precautions:

  • Improper use or unauthorized repairs void the warranty.
  • All programming and maintenance services must be performed by qualified technicians.
  • The power supply line must be protected with a magnetic-thermal switch or 5A fuses. An earth leakage circuit breaker is recommended.
  • Ensure correct motor pole connections (OPEN/CLOSE) to prevent incorrect gate movement.
  • Safety devices require N.C. (normally closed) contacts. If multiple devices are used, connect them in parallel.
  • For encoder use, it is recommended to read the manual for correct implementation.

Casit KEQS08 Specifications

General IconGeneral
BrandCasit
ModelKEQS08
CategoryReceiver