ERROR CODES/MESSAGES APX 1I
ERROR MESSAGE REJECT REASON CHECK
ID ERROR Unknown Currency CIS/LED Bar
DIFF Different Denomination ---
CHAIN Bills fed too close to each other Feeding Mechanism
DOUBLE Two or more bills passed together
Feed Gap, Double
Sensors, Deformed/
Taped Note
HALF Half Bill detected
Ps1/Ps2, Torn Or
Deformed Note
SKEW Bills were skewed
Feed Mechanism,
Improper Loading Of
Notes In Hopper
SRL MISMATCH
Serial numbers of the bill did not
match
ADC (Main Board)
NO SRL No serial number found on the bill Face of bill
ERROR MESSAGE SOLUTION
JAM1 Open upper door and remove bill(s) from path
JAM2 Open lower door and remove bill(s) from path
FEED ERROR Remove Bills from Hopper. Adjust Feeding Mechanism
MOTOR ERROR
Make sure path is clear and all belts are connected properly.
Test Motor in both directions using the Service Menu
70