CassidaPRO Zeus: Service Manual
2018 Cassida Corporation. All rights reserved.
Rev: 09/05/2018
cassidapro.com/partner/
• Place notes on the hopper. The Zeus will count the bills and collect data. The
data is stored in an internal buffer and copied to the USB external storage
media automatically. If the internal buffer capacity reaches its limit, the Zeus
will display “Waiting” and stop collecting data. It will resume collecting data
automatically when the buffer gets enough free space.
• Do not remove the USB storage medium while downloading or buffering state.
• Collect data at least 12 times for each genuine note, 3 times per orientation:
• Once at the left side of the hopper
• Once at the center of the hopper
• Once at the right side of the hopper
[2] Fake Note
NOTE: This menu is only for collecting data on fake bills. Never attempt to collect data
with a genuine bank note. Place the fake notes on the hopper, the Zeus will count them
and collect data. Proceed using the same steps as outlined above for the fake note.
Ensure the code is correct, and that the bill being scanned is actually a suspect note.
SOFTWARE VERSION
• This menu option provides the technician with information about the Zeus’ internal
hardware and software configuration. This screen may be used to determine the
currently installed software version, UI version, hardware revisions, and datapack
library revisions per currency.
1-2 Selector
• Test the diverter by changing the direction to the stacker or the reject pocket.
1-3 CIS LED
• Turn on/off the CIS LED and back light LED. Repeatedly press [2] to check the LEDs in
this order:
1. Back light
2. Blue CIS
3. Red CIS
4. UV CIS
5. Green CIS
6.9.DATA DOWNLOAD