EasyManua.ls Logo

Cerlic BB2 - 9. Jumper Settings; Analog Outputs

Cerlic BB2
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 8 -
9. Jumper settings
BB2 has five jumpers to configure the board.
Jumpers on BB2
ANALOG OUTPUTS
The two analog outputs of BB2 are default active, sourcing 4-20 mA into a load of
maximum 500 ohms. They are galvanic isolated from the rest of the system, but the
two channels use a common ground. Channel 2 can be jumperd to be passive, and fully
isolated sink 4-20 mA from an external supply of max 24V DC, by changing JP1 and
JP7.
Analog Output channel 2 JP1 JP7
Active, sourcing 1-3 and 2-4 1-2
Passive, sinking 1-2 and 3-4 3-4
Digital Inputs
3
1 2
3 4
1
1 5
2 6
External load
Passive
BB2 Active
Sourcing 4-20 mA
6 or 8
7 or 9
8
9
BB2 Passive
(Channel 2 only)
Sinking 4-20 mA
External load
External 24 VDC