EasyManuals Logo

CESAB C3E150 User Manual

Default Icon
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
chapter 5000
page 65
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
CODE ALARM DESCRIPTION
LIGHTS CARD (NOT SHOWN BY THE CONSOLE)
C1 STOP-OPEN Failure on the stop lights. Check the bulbs of the stopstreetlights and the
relevant cables.
C2 Not used.
C3 Not used.
C4 RETRO-OPEN Failure on the backup lights. Check the bulbs of the backup streetlights and
the relevant cables.
C5 C1+C4 Failure on the stop and the backup lights. Check the relevant bulbs and the
cables of both light types.
C6 Not used.
C7 Not used.
C8 Not used.
I / O CARD (NOT SHOWN BY THE CONSOLE)
81 TRACTION Incorrect start sequence (control valve version). Check:
INCORRECT START - forward, backward microswitches and relevant cables;
- parking brake micro and relevant cables.
82 LOGIC FAILURE Logic defect (control valve version).
83 PEDAL WIRE KO Failure on the acceleration potentiometer signal at rest. Check:
- traction potentiometer (could be damaged or not correctly calibrated);
- traction potentiometer wiring.
84 BAD MICROSWITCH
85 Not used.
86 Not used.
87 Not used.
88 PUMP INCORRECT START
89 TRACTION Alarm 81 + alarm 88
AND PUMP
INCORRECT START
ALARM COMBINATION
81-26 INCORRECT START traction pedal
56-88 INCORRECT START mechanic distributor