chapter 5000
page 19
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
CONNECTORS
A1 PCLRXD
A2 NCLRXD
A3 PCLTXD
A4 NCLTXD Console connector
A5 GND
A5 GND
A6 +12
A7 FLASH
A8 FLASH
C1 CAN-L Low level CAN-BUS voltage I/O.
C3 CAN-H High level CAN-BUS voltage I/O.
D1 Positive of lifting motor encoder power supply (+12V).
D2 Negative of lifting motor encoder power supply.
D3 Lifting motor encoder phase A.
D5 Lifting motor encoder phase B.
E4 CM Common of LIFT ENABLE / 1st SPEED / 2nd SPEED/ 3rd SPEED /4th SPEED /
HYDRO / SR microswitches.
E12 HYDRO REQ. Input for hydraulic steering request. Active high.
F1 KEY Connected to +Batt through the series costituited by the key switch, the protection
diode and a 10A fuse
F5 SAFETY If not connected to -Batt the MC coil power output will be disabled.
Can also be used as a general purpose input.
F6 PTHERM Input for motor temperature sensor.
F11 GND -Batt.
F12 NTHERM -Batt.

Table of Contents