© Cesab 8 – 8 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
2:006
Saving to memory
failed.
Saving to memory
failed because low
battery voltage.
Battery voltage
below 15 V at the
time of saving
Not influenced
1: Battery
connector
disconnected
from truck that
is started
2: Voltage loss
on supply to
A5
3: The battery is
defective
4: Battery
parameter
#107 has an
erroneous
value
1: Connect the battery connector.
2: Check battery voltage
• Check the voltage using the
built-in test procedure and
comparing with value from
external volt meter
• Check connectors, joints and
splices for damage or corrosion.
• Check fuses F1 and F50
3: Check the battery.
4: Check parameters
• Check that factory parameters
are set according to the truck
configuration.
• Check that other parameters
are set correctly.
2:007
Internal program
error A5
Not influenced
Internal program
error
• Create a truck report. Send a
report to the manufacturer.
• Update the truck software to the
latest version.
2:008
Internal program
error A5
Not influenced
Internal program
error
• Create a truck report. Send a
report to the manufacturer.
• Update the truck software to the
latest version.
2:009
Internal program
error A5
Not influenced
Internal program
error
• Create a truck report. Send a
report to the manufacturer.
• Update the truck software to the
latest version.
Code Description
Truck
behaviour
Error cause(s) Procedure
https://www.forkliftpdfmanuals.com/