© Cesab 8 – 52 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Voltage across contactor coil
[Q25], but no current through
the coil.
Interruption in the pump
contactor coil [Q25]
Replace the pump contactor
Cont'd. Pump contactor [Q25] does not close
Symptom Influencing elements Possible cause/Remedy