EasyManua.ls Logo

Chamberlain MIRACLE-ONE - TROUBLESHOOTING; Check the Fuses

Chamberlain MIRACLE-ONE
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
Check the Fuses
If the gate is not moving in any direction be sure to check all of the LED displays on the control board. If the board
power or charging power LEDs are on, change the corresponding fuse on the right side of the board. If the motor
will not work, and all LED's on the board are ok, check the fuse on the left side of the board and replace if
necessa
ry.
Master / Slave
Single
Caution: If left side board fuse is blowing on a regular basis, make sure operator is operating smoothly.
Verify traveler carriage washer placement (Page 12). Check motor wire connections.
Replace the fuses only with specified rating (Supplied by Chamberlain Elite).
8 Amps
2 Amps 1.5 Amps
3 Amps 1.5 Amps
Change Fuse
15 Amps
Change Fuse