Mounting Specifications - Pedestal Mount Stations
IMPORTANT: Use a ChargePoint Concrete Mounting Template (CMT) when installing a new
pedestal mount charging station or replacing an existing non-ChargePoint pedestal mount
station. You do not need a CMT if you are installing a wall mount charging station or replacing an
existing ChargePoint station.
The concrete pad must either be designed to be site-specific or must meet these specifications:
l
Must not be installed in asphalt
l
Mounting surface must be smooth
l
Mounting surface cannot exceed a slope of 6 mm per 300 mm (0.25 in per ft)
l
The concrete base must measure at least 600 mm (2 ft) on all sides
l
Epoxy anchors can be used (installations in existing concrete)
l
No expanding bolts are used
l
Consult a civil engineer to ensure sufficient volume and strength of concrete; (installations in existing
concrete)
IMPORTANT: If the existing pad does not meet the specifications above, a structural engineer
must inspect and approve the pad for CP6000 charging station dimensions and weight.