DF II Series User Manual 73
CONTACT CLOSURE - ON/OFF
If this option is selected, the DFS II Series gauge will
not freeze its display when a switch event has oc-
curred. There is no Contact Closure Mode available.
Select F1 (ON/OFF) to enable or disable contact
closure.
CONTACT CLOSURE - OPEN TYPE
If this option is selected, the DFS II Series gauge
will freeze its display when a switch has been
opened (break). Select F1 (OPEN) to specify
the DFS II to look for a switch “break”. Select F2
(Back) to turn contact closure Off.
CONTACT CLOSURE - CLOSE TYPE
If this option is selected, the DFS II Series gauge
will freeze its display when a switch has been
closed (make). Select F1 (CLOSE) to specify
the DFS II to look for a switch “make”. Select F2
(Back) to turn contact closure Off.