Front Panel Operation
CHCNAV iBase GNSS USER GUIDE | 2023-2 P a g e | 24
Mode
Ultra Base
Base External UHF
Base Internal UHF
Base APIS
Base External UHF & APIS
Rover APIS
Rover UHF
Rover NTRIP
Back
• Press Enter button to enter the
configuration screen of the selected
working mode.
• More operation information, see 3.2
Configure the Working Mode.
Static
Set on/off
Press Enter button to switch static
measurement on or off.
Recording 00:00
Display the time of recording
Advanced
Sample
Press Enter to change sample interval
(1s, 2s, 5s, 10s, 15s, 30s, 1m)
Elev Mask 10
degree
Press Enter button to change the mask
degree from 0 degree to 90 degrees.
Duration
1440min
Press Enter button to enter Duration
Time Setting screen.
• In the Duration Time Setting screen,
press Fn button to move to the
character of the duration time value
user want to make change, and then
press Enter button to change from 0 to
9. After the change has been done, user
can press Fn button to move to OK field,
and then Press Enter button to save the
change and back to the second-level
menu; or press Fn button to move to
Cancel field and press Enter button to
cancel the change and back to the
second-level menu.
Measurement
phase Center
Press Enter button and switch height
between oblique, vertical, phase center.
Antenna
Height
0.0000m
Press Enter button and input the
measured antenna height.

Table of Contents