High Power DC Electronic Load 63200 Series Operation & Programming Manual
Description Set the load on time of program file.
Syntax PROGram:ONTime <NRf>[suffix]
Parameters 30 Sec
Example PROG:ONT 10
PROG:ONT 100mS
Query Syntax PROGram:ONTime?
Return Parameters <NR2> [Unit=Sec]
Query Example PROG:ONT?
Return Example 10
PROGram:OFFTime
Description Set the load off time of program file
Syntax PROGram:OFFTime <NRf>[suffix]
Parameters 30 Sec
Example PROG:OFFT 20
PROG:OFFT 200mS
Query Syntax PROGram:OFFTime?
Return Parameters <NR2> [Unit=Sec]
Query Example PROG:OFFT?
Return Example 0.2
PROGram:PF:DELay
Description Set the pass/fail measurement delay time of program file.
Syntax PROGram:PF:DELay <NRf>[suffix]
Parameters 60 Sec
Example PROG:PF:DELay 20
PROG:PF:DELay 200mS
Query Syntax PROGram:PF:DELay?
Return Parameters <NR2> [Unit=Sec]
Query Example PROG:PF:DEL?
Return Example 0.2
PROGram:PF:TIME
Description Set the pass/fail measurement time of program file
Syntax PROGram:PF:TIME <NRf>[suffix]
Parameters 60 Sec
Example PROG:PF:TIME 20
PROG:PF:TIME 200mS
Query Syntax PROGram:PF:TIME?
Return Parameters <NR2> [Unit=Sec]
Query Example PROG:PF:TIME?
Return Example 0.2