Language Dictionary
7.2.5 LOAD Sub-system
LOAD
[:STATe]
:SHORt
[:STATe]
:KEY
:PROTection
:CLEar
:SAVE
LOAD[:STATe]
Description The LOAD command makes the electronic load active on or off.
Syntax LOAD:[STATe] <NR1 | CHAR >
Parameters 0 | OFF, 1 | ON
Example LOAD ON Activate the electronic load.
LOAD OFF Inactivate the electronic load.
Query Syntax LOAD:[STATe]?
Return Parameters 0 | 1
Query Example LOAD? Return if the electronic load is active.
Return Example 1 (ON)
LOAD:SHORt[:STATe]
Description Activate or inactivate short-circuited simulation.
Syntax LOAD:SHORt:[STATe <NR1 | CHAR >]
Example LOAD:SHOR 1 Activate short-circuited simulation.
LOAD:SHOR OFF Inactivate short-circuited simulation.
Parameters 0 | OFF, 1 | ON
Query Syntax LOAD:SHORt:[STATe]?
Return Parameters 0 | 1
Query Example LOAD:SHOR? Return the short-circuit simulation state.
Return Example 1 (ON)
LOAD:SHORt:KEY
Description Set the short key mode in the electronic load.
Syntax LOAD:SHORt:KEY TOGGLE <NR1 | CHAR >
Parameters 0 | HOLD, 1 | TOGGLE
Example LOAD:SHOR:KEY TOGGLE Set short key mode to Toggle.
LOAD:SHOR:KEY 0 Set short key mode to Hold.
Query Syntax LOAD:SHORt:KEY?
Return Parameters 0 | 1
Query Example LOAD:SHOR:KEY? Return the short key mode in the
electronic load.
Return Example 1 (TOGGLE)
LOAD:PROTection?
7-15