7.2.13 VOLTage Sub-system
VOLTage
:CURRent
:L1
:L2
:MODE
VOLTage:CURRent
Description Set the current limit for constant voltage mode.
Syntax VOLTage:CURRent
Parameters For valid value range refer to respective specification.
Example VOLT:CURR 3 Set loading current limit to 3A during
constant voltage mode.
VOLT:CURR MAX Set loading current limit to the max.
value during constant voltage mode.
VOLT:CURR MIN Set loading current limit to the min.
value during constant voltage mode.
Query Syntax VOLTage:CURRent?
Return Parameters <NR2> [Unit=Ampere]
Query Example VOLT:CURR?
Return Example 3
VOLTage:L1/L2
Description Set voltage of static load during constant voltage mode.
Syntax VOLTage:L1
VOLTage:L2
Parameters For valid value range refer to respective specification.
Example VOLT:L1 8V Set the voltage of load L1 to 8V.
VOLT:L2 24V Set the voltage of load L2 to 24V.
VOLT:L1 MAX Set the voltage of load L1 to the max. value.
VOLT:L2 MIN Set the voltage of load L2 to the min. value.
Query Syntax VOLTage:L1?
VOLTage:L2?
VOLTage:L1? MAX
VOLT:L2? MIN
Return Parameters <NR2> [Unit=Voltage]
Query Example VOLT:L1? Return the set voltage value of load L1.
Return Example 0
VOLTage:MODE
Description Set the response speed of CV mode.
Syntax VOLTage:MODE <NR1 | CHAR>
Parameters 0 | SLOW, 1 | FAST
Example VOLT: MODE 1
VOLT:MODE SLOW