Language Dictionary
7.2.1 CONFigure Sub-system
CONFigure
:AUTO
:LOAD
:MODE
:DISPlay
:KEY
:REMote
:SAVE
:SOUNd
:VOLTage
:LATch
:RESet
:ON
:POLarity
:RANGe
CONFigure:AUTO:LOAD
Description Set if the load module will do Auto Load On during power-on.
Syntax CONFigure:AUTO:LOAD <NR1 | CHAR>
Parameters 0 | OFF, 1 | ON
Example CONF:AUTO:LOAD ON Start Auto Load On during power on.
CONF:AUTO:LOAD OFF Close Auto Load On during power on.
Query Syntax CONFigure:AUTO:LOAD?
Return Parameters 0 | 1
Query Example CONF: AUTO: LOAD?
Return Example 0 (OFF) Return the status of Auto Load On
CONFigure:AUTO:MODE
Description Set type of Auto Load On as LOAD ON or PROGRAM ON.
Syntax CONFigure:AUTO:MODE <NR1 | CHAR>
Parameters 0 | PROGRAM, 1 | LOAD
Example CONF:AUTO:MODE LOAD Set Auto Load On as general
Load On.
CONF:AUTO:MODE PROGRAM Set Auto Load On as
Program On.
Query Syntax CONFigure:AUTO:MODE?
Return Parameters 0 | 1
Query Example CONF:AUTO:MODE? Return the execution type of
Auto Load On.
Return Example 0 ( PROGRAM)
CONFigure:DISPlay
Description Set measure display mode
Command Syntax CONFigure:DISPlay <NR1 | CHAR>
7-5