CURR:STAT:FALL 1A/µS Set fall slew rate to 1A/µS for
static load.
Query Syntax CURRent:STATic:RISE?
CURRent:STATic:FALL?
CURRent:STATic:RISE? MAX
CURRent:STATic:FALL? MIN
Return Parameters <NR2> [Unit=A/µS]
Query Example CURR:STAT:RISE? Return the rise slew rate of static
load.
Return Example 2.5
CURRent:DYNamic:L1/L2
Description Set Dynamic Load Current during constant current mode.
Syntax CURRent:DYNamic:L1 <NRf+>[suffix]
CURRent:DYNamic:L2 <NRf+>[suffix]
Parameters For valid value range refer to respective specification.
Example CURR:DYN:L1 20 Set dynamic load parameter L1 = 20A.
CURR:DYN:L2 10 Set dynamic load parameter L2 = 10A.
CURR:DYN:L1 MAX Set dynamic load parameter L1 = max.
value
CURR:DYN:L2 MIN Set dynamic load parameter L2 = min.
value.
Query Syntax CURRent:DYNamic:L1?
CURRent:DYNamic:L2?
CURRent:DYNamic:L1? MAX
CURRent:DYNamic:L2? MIN
Return Parameters <NR2> [Unit=Ampere]
Query Example CURR:DYN:L1? Return the setting current in dynamic
load L1.
Return Example 35.6
CURRent:DYNamic:RISE/FALL
Description Set current slew rate of constant current dynamic mode.
Syntax CURRent:DYNamic:RISE <NRf+>[suffix]
CURRent:DYNamic:FALL <NRf+>[suffix]
Parameters For valid value range refer to respective specification.
Example CURR:DYN:RISE 2.5 Set rise slew rate to 2.5A/µS.
CURR:DYN:FALL 1A/µS Set fall slew rate to 1A/µS.
CURR:DYN:RISE MAX Set rise slew rate to the maximum
value of dynamic load.
CURR:DYN:FALL MIN Set fall slew rate to the minimum value
of dynamic load.
Query Syntax CURRent:DYNamic:RISE?
CURRent:DYNamic:FALL?
CURRent:DYNamic:RISE? MAX
CURRent:DYNamic:FALL? MIN
Return Parameters <NR2> [Unit=A/µS]
Query Example CURR:DYN:RISE? Return the rise slew rate of dynamic
7-11