3.4 SAFE OPERATIONS
3.5 CINDERELLA FREEDOM SAFETY FEATURES
• The incineration process is inactive while the toilet lid is open. The incineration will not start until the seat and
lid are closed.
• The hatch to the incineration chamber CANNOT remain open while the toilet is still hot (e.g. during cleaning).
This is only possible when the toilet has cooled down and the fan has stopped.
• Should a ventilation problem arise and the internal temperature of the toilet increases to more than 105 °C,
incineration will be interrupted and a warning message displayed. This situation requires a manual reset to
ensure the ventilation issue is addressed before the toilet can be used again.
• If the ash container is improperly positioned after emptying, incineration will not start and a warning light
and message will be displayed.
• If the combustion chamber hatch mechanism gets jammed or is prevented from closing properly,
incineration will not start and an error message will be displayed.
• The Cinderella Freedom’s smart software includes a ’’watchdog’’ function that monitors the temperature
while incineration is taking place. If any deviations from the normal temperature range are detected, this will
immediately result in the incineration stopping and a warning message being displayed.
CAUTION!
• The ash container in the toilet will become very hot when the toilet is in use. Make sure
the safety cover is in place when the toilet is in use. Do not empty the ash container
until the toilet has cooled completely.
• The seat and lid do not have a soft-close function. Take care not to crush your hands or
ngers when closing the lid and seat.
NB!
Danger of poor incineration and overheating of the system!
• Always use a new bowl liner when using the toilet.
• Always ensure sucient ventilation so that the heat generated during the operation
can dissipate.