2.3 FLUE PIPE INSTALLATION
NB!
• This appliance must be installed in accordance with AS/NZS 5601.1.
• This appliance must be installed with DuraVent ue pipes, materials must comply with
AS/NZS 5601.1.
• This appliance must not be installed in a mobile or portable installation (e.g. mobile
home, mobile shed, recreational vehicle or caravan).
• This appliance must not be installed in locations with other air-dependent equipment
that could adversely aect the system, such as ventilators or open re sources.
• This appliance must only be installed by a licensed/authorised person.
• The toilet must be placed on a rm and level base.
• Your Cinderella Freedom incinerating toilet can be installed on a heated oor.
• This appliance must be secured to the oor (see section 2.1 of this manual).
• When installed in environments where condensation may accumulate, adequate
condensation draining must be installed.
• The T-bend must be accessible when installed, so that the drainage pipe can be rinsed,
and the ue pipe cleaned.
CAUTION!
Before cutting any holes, always check that you will not cut any electrical wiring or water
pipes.
NOTE!
• This appliance is designed and certied to be installed with DuraVent’s Type B Gas
Vent system. For detailed instruction on how to install the ue pipes, tolerances and
ue pipe specications please refer to DuraVent’s installation manuals, which can be
downloaded from their website: duravent.com/installation-instructions/
• This manual refers to a selection of pipes and accessories from DuraVent’s type B
system, which t the special parts supplied with the toilet. It is important to familiarize
yourself with the various components and restrictions, in order to achieve the best
possible installation and correct product functionality.