Raption
89Instruction Manual
Parameter Description
Use OCPP time
synchronization
Enabled: Synchronization of date and time.
Disabled: Synchronization of date and time.
Note: Date and Time is sent from backend on each heartbeat
response.
Energy for MeterValues
Partial: Sends partial energy consumption while vehicle is
charging.
Total: sends the actual count of the total accumulated en-
ergy meter.
Stop charge if StartTransaction
rejects the user
Enabled: Stop existing charge transaction after response
from backend (StartTransaction.conf) when user is blocked,
expired or Invalid.
Disabled: Charge transaction does not stops even if back-
end rejects the user. (StartTransaction.conf)
Note: Set this option according to your backend system.
Authorize Remote Tx Requests
Enabled: The Charge Point asks for authorization when the
Central System sends a remote start.
Disabled: The Charge Point starts the Charge Transaction
when the Central System sends a remote start.
Stop charge if StartTransaction
replies ConcurrentTx
Enabled: Stop existing charge transaction after response
from backend (StartTransaction.conf) when user has already
involved in another transaction.
Disabled: Charge transaction does not stops even if back-
end rejects the user. (StartTransaction.conf)
Note: Set this option according to your backend system.

Other manuals for Circutor Raption Series