Raption
90
Instruction Manual
Parameter Description
ID Tag Endianness Storage type for system data. Able to choose between (LIT-
TLE>BIG)
Include Power Active Import in
MeterValues
Enabled: Send power (Power.Active.Import) and energy (En-
ergy.Active.Import.Register) consumed by the vehicle within
meter values requests.
Disabled: Only energy consumed is sent within meter values
request.
Energy for Start/Stop
transaction
Partial: Consumed value of energy by the vehicle sent be-
tween start and stop.
Total: count of the total accumulated energy meter sent be-
tween start and stop.
User confirmation on HMI
required on Remote Start
Transaction
Enabled: Charge point sends an authorization request be-
fore starting a new remote charge transaction request.
Disabled: Charge point starts a new remote charge transac-
tion without authorization request.
Authorize always in offline
mode
Enabled: If user is not present locally in the local white-list
and charge point cannot ask to the backend, user is allowed
to start a new charge transaction.
Disabled: If user is not present locally in the local white-list
and charge point cannot ask to the backend, the user is not
allowed to start a new charge transaction.
Authorization check order
Local: ID authorization has first place on the local white-list.
If the user does not exist locally, then in second place back-
end is asked to obtain the authorization.
CS: ID authorization is always asked to the backend.
Note: This setting only applies when Charge Point is online;
otherwise the authorization is only locally.