5-6
Cisco 7600 Series Router SIP, SSC, and SPA Hardware Installation Guide
OL-5052-08
Chapter 5 Installing and Removing a SIP
Online Insertion and Removal
To activate a SPA and its interfaces after the SPA has been deactivated, use the following command in
global configuration mode:
Verifying Deactivation and Activation of a SPA
When you deactivate a SPA, the corresponding interfaces are also deactivated. This means that these
interfaces will no longer appear in the output of the show interface command.
To verify the deactivation of a SPA, enter the show hw-module subslot all oir command in privileged
EXEC configuration mode. Observe the Operational Status field associated with the SPA that you want
to verify.
In the following example, the SPA located in subslot 1 of the SIP in slot 2 of the router is administratively
down from the hw-module subslot shutdown command:
Router# show hw-module subslot all oir
Module Model Operational Status
-------------- ------------------ -------------------------
subslot 2/0 SPA-4XOC3-POS ok
subslot 2/1 SPA-4XOC3-ATM admin down
To verify activation and proper operation of a SPA, enter the show hw-module subslot all oir command
and observe “ok” in the Operational Status field as shown in the following example:
Router# show hw-module subslot all oir
Module Model Operational Status
-------------- ------------------ -------------------------
subslot 2/0 SPA-4XOC3-POS ok
subslot 2/1 SPA-4XOC3-ATM ok
Deactivation and Activation Configuration Examples
This section provides the following examples of deactivating and activating SIPs and SPAs:
• Deactivation of a SIP Configuration Example, page 5-7
• Activation of a SIP Configuration Example, page 5-7
• Deactivation of a SPA Configuration Example, page 5-7
• Activation of a SPA Configuration Example, page 5-7
Command Purpose
Router(config)# no hw-module subslot
slot/subslot shutdown
Activates the SPA and its interfaces in the specified slot
and subslot of the SIP, where:
• slot—Specifies the chassis slot number where the
SIP is installed.
• subslot—Specifies subslot number on a SIP where
a SPA is installed.