For IP-30 compliance: If you use ETSI brackets, you can insert the rubber plugs in the same holes as shown
in Figure 11 before installing the brackets.
Note
Rack-Mounting the Switch
After you attach the brackets on the switch, attach the brackets to the rack.
Figure 13: Rack-Mounting
After the switch is mounted in the rack:
1. Wire the switch to a power source. See Wiring the Power Source, on page 44.
2. Connect the ports. See Connecting Devices to the Ethernet Ports, on page 34.
3. Attach the cable guide to prevent the cables from obscuring the LED panels on the devices in the rack.
Use the supplied black screw to attach the cable guide to the left or right bracket.
For configuration instructions about the CLI setup program, see Configuring the Switch with the CLI Setup
Program, on page 65.
Wall-Mounting
Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware
or to follow the correct procedures could result in a hazardous situation to people and damage to the system.
Statement 378
Warning
For mounting railway-application equipment and for EN50155 standard compliance, the switch must be
installed only in a rack mid-mounting position. If you install the switch in a front rack-mounting (cable side
or power supply side) position or in a wall-mounting position, a mechanical failure can occur that results in
the switch becoming detached from the rack. Statement 403
Warning
If the switch is wall-mounted in an enclosure, follow these minimum clearances:
Cisco IE 4010 Switch Hardware Installation Guide
24
Switch Installation
Rack-Mounting the Switch