CHAPTER 8
Technical Specifications
This chapter contains the following sections:
• Switch Specifications, on page 77
• Power-Supply Module Specifications, on page 79
• Alarm Ratings, on page 79
Switch Specifications
Table 15: Cisco IE 4010 Switch Specifications
Environmental Ranges
-40°C to +74°C
• -40°C to +75°C (Vented Enclosure Operating- 40 LFM Air Flow)
• -40°C to +60°C (Sealed Enclosure Operating- 0 LFM Air Flow)
• -34°C to +75°C (Fan or Blower equipped Enclosure Operating- 200
LFM Air Flow)
• -40°C to +85°C (IEC 60068-2-2 Environmental Type Tested to
+85°C for 16 hours)
The maximum operating temperature of the switch varies
depending on the type of SFP module that you use.
Note
Operating temperature
Operating
temperatures
exceeding 60°C are
not covered by the
product safety
certifications and
approvals.
However, the switch
can function in the
installations under
the environmental
conditions listed.
Note
–40 to 185°F (–40 to 85°C)Storage temperature
5 to 95% (noncondensing)Relative humidity
Up to 13,800 ft (3049 m)Operating altitude
Up to 15,000 ft (4570 m)Storage altitude
1.75 in. (4.4 cm)Thermal spacing
50G at 11ms, half sine and 200G ar 2.11ms, half sine.Operational shock
Cisco IE 4010 Switch Hardware Installation Guide
77