Equipment That You Need
Torque driver(s) capable of 5 to 35 in-lbs
Ring, spade, or flanged spade terminal (terminals should be insulated)
Ring terminal (such as Tyco part number 2-34158-1 for 16 14 AWG or 2-34852-1 for 12 10
AWG wire)
Spade terminal (such as Tyco part number 54367-2 for 16 14 AWG wire)
Flanged spade terminal (such as Tyco part number 2-324165-1 for 16 14 AWG wire or 1-324581-1
for 12 10 AWG wire)
Use the 16-14 AWG wire and appropriate terminals for the AC or high-voltage DC power supply
Use the12-10 AWG wire and appropriate terminals for the low-voltage DC power supply
Crimping tool (such as Thomas & Bett part number WT2000, ERG-2001)
6-gauge copper ground wire
12-AWG wire (minimum) for the low-voltage power-supply module and 16-AWG (minimum) wire for
the high-voltage power-supply module
For power source connections, use wires rated for at least 194°F (90°C).
UL- and CSA-rated style 1007 or 1569 twisted-pair copper wire
Wire-stripping tools for stripping 6-, 10-, 12-, 14-, and 16-gauge wires.
Number-2 Phillips screwdriver
Flat-blade screwdriver
Obtain these necessary tools and equipment:
Ratcheting torque screwdriver with a number-2 and a number-1 Phillips head that exerts up to 15
pound-force inches (lbf-in.) or 240 ounce-force inches (ozf-in.) of pressure.
Panduit crimping tool with optional controlled-cycle mechanism (model CT-720, CT-920, CT-920CH,
CT-930, or CT-940CH).
Wire-stripping tools.
12-gauge copper ground wire (insulated or noninsulated) when using the single-ground connection.
6-gauge copper ground wire (insulated or noninsulated) when using the dual-ground connection.
For the dual ground connection, also use the supplied dual-hole lug from the accessory kit.
Four leads of 16-gauge copper wire.
Grounding the Switch
Follow the grounding procedures at your site and observe these warnings:
Cisco IE 4010 Switch Hardware Installation Guide
40
Power Supply Installation
Equipment That You Need

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-4010-16S12P and is the answer not in the manual?

Cisco IE-4010-16S12P Specifications

General IconGeneral
BrandCisco
ModelIE-4010-16S12P
CategorySwitch
LanguageEnglish

Related product manuals