EasyManuals Logo
Home>Cisco>Switch>IE-4010-16S12P

Cisco IE-4010-16S12P User Manual

Cisco IE-4010-16S12P
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
CHAPTER 5
Hazardous Location Installation Information
This chapter contains the following sections:
Hazardous Area Installation Warnings, on page 55
North American Hazardous Location Approval, on page 57
EMC Environmental Conditions for Products Installed in the European Union, on page 58
Hazardous Locations Standards, on page 58
Hazardous Area Installation Warnings
When installed in a Class I. Div/Zone 2 hazardous location environment, this equipment must be installed in
a min. IP54, ATEX certified enclosure.
Caution
Airflow around the switch must be unrestricted. To prevent the switch from overheating, there must be the
following minimum clearances:
Top and bottom: 2.0 in. (50.8 mm)
Sides: 2.0 in. (50.8 mm)
Front: 2.0 in. (50.8 mm)
Caution
Contact your Cisco Technical Assistance Centre (TAC) if tighter spacings are required.
When installed in a Class I. Div/Zone 2 hazardous location environment. this equipment must be installed in
a pollution degree 2 environment per IEC 60664-1)
Caution
This equipment is suitable for use in Class I. Division 2. Groups A, B. C. D. or only nonhazardous locations.
Caution
Cisco IE 4010 Switch Hardware Installation Guide
55

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-4010-16S12P and is the answer not in the manual?

Cisco IE-4010-16S12P Specifications

General IconGeneral
BrandCisco
ModelIE-4010-16S12P
CategorySwitch
LanguageEnglish

Related product manuals