CHAPTER 5
Hazardous Location Installation Information
This chapter contains the following sections:
Hazardous Area Installation Warnings, on page 55
North American Hazardous Location Approval, on page 57
EMC Environmental Conditions for Products Installed in the European Union, on page 58
Hazardous Locations Standards, on page 58
Hazardous Area Installation Warnings
When installed in a Class I. Div/Zone 2 hazardous location environment, this equipment must be installed in
a min. IP54, ATEX certified enclosure.
Caution
Airflow around the switch must be unrestricted. To prevent the switch from overheating, there must be the
following minimum clearances:
Top and bottom: 2.0 in. (50.8 mm)
Sides: 2.0 in. (50.8 mm)
Front: 2.0 in. (50.8 mm)
Caution
Contact your Cisco Technical Assistance Centre (TAC) if tighter spacings are required.
When installed in a Class I. Div/Zone 2 hazardous location environment. this equipment must be installed in
a pollution degree 2 environment per IEC 60664-1)
Caution
This equipment is suitable for use in Class I. Division 2. Groups A, B. C. D. or only nonhazardous locations.
Caution
Cisco IE 4010 Switch Hardware Installation Guide
55

Table of Contents

Other manuals for Cisco IE 4010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE 4010 and is the answer not in the manual?

Cisco IE 4010 Specifications

General IconGeneral
BrandCisco
ModelIE 4010
CategorySwitch
LanguageEnglish

Related product manuals