EasyManua.ls Logo

Cisco MX700 - Xconfiguration Audio Output Line [1; Xconfiguration Audio Ultrasound Maxvolume

Cisco MX700
241 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
Copyright © 2017 Cisco Systems, Inc. All rights reserved. 51
Cisco TelePresence MX700 and MX800
API Reference Guide
xConfiguration Audio Output Line [1..6] Equalizer Mode
Define the equalizer mode for the audio source that is connected to the output line.
Requires user role: ADMIN, INTEGRATOR
Default value: Off
USAGE:
xConfiguration Audio Output Line n Equalizer Mode: Mode
where
n
: Unique ID that identifies the audio line output. Range: 1..6
Mode
: Off/On
Off: No equalizer.
On: Enable the equalizer for the audio output line.
xConfiguration Audio Output Line [1..6] Level
Define the audio level on the line output connector.
See the Audio Level table in the Physical Interface Guide for Cisco TelePresence SX80 for a
complete overview of the values represented in dB.
Requires user role: ADMIN, INTEGRATOR
Default value: -10
USAGE:
xConfiguration Audio Output Line n Level: Level
where
n
: Unique ID that identifies the audio line output. Range: 1..6
Level
: Integer (-24..0)
Select a value between -24 and 0, in steps of 1 dB.
xConfiguration Audio Output Line [1..6] Mode
Define the mode for the audio line output.
Requires user role: ADMIN, INTEGRATOR
Default value: On
USAGE:
xConfiguration Audio Output Line n Mode: Mode
where
n
: Unique ID that identifies the audio line output. Range: 1..6
Mode
: Off/On
Off: Disable the audio line output.
On: Enable the audio line output.
xConfiguration Audio Ultrasound MaxVolume
This setting applies to the Intelligent Proximity feature. Set the maximum volume of the ultra-
sound pairing message.
Requires user role: ADMIN, INTEGRATOR
Default value: 70
USAGE:
xConfiguration Audio Ultrasound M axVolume: MaxVolu me
where
MaxVolume
: Integer (0..90)
Select a value in the specified range. If set to 0, the ultrasound is switched off.
Introduction