Cisco Nexus 7000 Series NX-OS High Availability Commands
out-of-service
HACR-5
Cisco Nexus 7000 Series NX-OS High Availability Command Reference, Release 5.x
OL-23374-01
out-of-service
To power off a supervisor module in the Cisco NX-OS software, use the out-of-service command.
out-of-service module module-number
Syntax Description
Defaults None
Command Modes Global configuration mode
Supported User Roles network-admin
vdc-admin
Command History
Usage Guidelines
This command is not supported on line card modules. For line card modules, use the poweroff command.
You can use the out-of-service command only in the default virtual device context (VDC).
Use this command to safely remove a module from service in the software. Before bringing a module
back into service, you must remove the physical hardware module from the chassis and reinsert it.
This command does not require a license.
Examples This example shows how to take a supervisor module out of service:
switch# configure terminal
switch(config)# out-of-service module 3
Related Commands
module Specifies an I/O module.
module-number Module number. The range is from 1 to 18.
Release Modification
4.0(1) This command was introduced.
Command Description
poweroff Shuts down a supervisor of a line card module in the Cisco NX-OS
reload module Reloads a module in a device.