EasyManuals Logo

Cisco SF350-24P Administration Guide

Cisco SF350-24P
762 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #224 background imageLoading...
Page #224 background image
Port Management
UDLD
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4 177
10
Undetermined—The system cannot determine the state of the port, because one of the
following is occurring:
- The neighbor does not support UDLD.
or
- The local device does not receive traffic from the neighbor.
The UDLD action in this case depends on the UDLD mode of the device as explained
below.
UDLD supports the following modes of operation:
Normal
If the link state of the port is determined to be bi-directional and the UDLD
information times out while the link on the port is still up, UDLD tries to re-establish
the state of the port.
Aggressive
If the link state of the port is determined bi-directional and the UDLD information
times out, UDLD shuts down the port after an extended period of time, when it can
determine that the link is faulty. The port state for UDLD is marked as undetermined.
UDLD is enabled on a port when one of the following occurs:
The port is a fiber port and UDLD is enabled globally.
The port is a copper port and you specifically enable UDLD on it.
How UDLD Works
When UDLD is enabled on a port, the following actions are performed:
UDLD initiates the detection state on the port.
In this state, UDLD periodically sends messages on every active interface to all
neighbors. These messages contain the device ID of all known neighbors. It sends
these messages according to a user-defined message time.
UDLD receives UDLD messages from neighboring devices. It caches these messages
until the expiration time (3 times message time) has passed. If a new message is
received before the expiration time, the information in that message replaces the
previous one.

Table of Contents

Other manuals for Cisco SF350-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SF350-24P and is the answer not in the manual?

Cisco SF350-24P Specifications

General IconGeneral
ModelSF350-24P
CategorySwitch
PoE Budget195W
LayerLayer 3
Power SupplyInternal
Uplink Ports2 x combo Gigabit SFP + 2 x Gigabit
MAC Address Table Size16K entries
Jumbo Frame Support9216 bytes
ManagementWeb, CLI, SNMP
FeaturesQoS, VLAN, IPv6, ACLs
Dimensions440 mm x 257 mm x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% non-condensing
Weight3.48 kg

Related product manuals