Status and Statistics
Diagnostics
70 Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4
5
- Open Cable—Cable is connected on only one side.
- Short Cable—Short circuit has occurred in the cable.
- Unknown Test Result—Error has occurred.
Distance to Fault—Distance from the port to the location on the cable where the fault
was discovered.
Operational Port Status—Displays whether port is up or down.
The Advanced Information block contains the following information, which is refreshed
each time you enter the page:
Cable Length—Provides an estimate for the length.
Pair—Cable wire pair being tested.
Status—Wire pair status. Red indicates fault and Green indicates status OK.
Channel—Cable channel indicating whether the wires are straight or cross-over.
Polarity—Indicates if automatic polarity detection and correction has been activated
for the wire pair.
Pair Skew—Difference in delay between wire pairs.
Optical Module Status
The Optical Module Status page displays the operating conditions reported by the SFP (Small
Form-factor Pluggable) transceiver.
The following GE SFP (1000Mbps) transceivers are supported:
MGBBX1: 1000BASE-BX-20U SFP transceiver, for single-mode fiber, 1310 nm
wavelength, supports up to 40 km.
MGBLH1: 1000BASE-LH SFP transceiver, for single-mode fiber, 1310 nm
wavelength, supports up to 40 km.
MGBLX1: 1000BASE-LX SFP transceiver, for single-mode fiber, 1310 nm
wavelength, supports up to 10 km.
MGBSX1:1000BASE-SX SFP transceiver, for multimode fiber, 850 nm wavelength,
supports up to 550 m.

Table of Contents

Other manuals for Cisco SF350-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SF350-24P and is the answer not in the manual?

Cisco SF350-24P Specifications

General IconGeneral
ModelSF350-24P
CategorySwitch
PoE Budget195W
LayerLayer 3
Power SupplyInternal
Uplink Ports2 x combo Gigabit SFP + 2 x Gigabit
MAC Address Table Size16K entries
Jumbo Frame Support9216 bytes
ManagementWeb, CLI, SNMP
FeaturesQoS, VLAN, IPv6, ACLs
Dimensions440 mm x 257 mm x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% non-condensing
Weight3.48 kg