35
Chapter 2 Printer Operation
Zebra® Emulation
Top Menu Sub Menu Default Menu Remarks
Global
conguration
– Cong Set 1 Cong Set 1
Cong Set 2
Cong Set 3
Sets the Cong Set.
Page Setup Print Speed 4 IPS 2 to 6 IPS [For CL-S521]
Printing speed setting.
(2 to 4 IPS with optional peeler.)
4 IPS 2 to 4 IPS [For CL-S531]
Printing speed setting.
Print Darkness 10 00 to 30 Print darkness setting
(printhead temperature)
Darkness Adjust 0 -10 to 10 Darkness command adjustment
Continuous Media
Length
4.00 inch
101.6 mm
0.25 to 32.00 inch
6.40 to 812.8 mm
Setting default length of continuous media,
if selected. ; the lower line is in metric mode.
Vertical Position 0.00 inch
0.0 mm
-1.00 to 1.00 inch
-25.4 to 25.4 mm
Print start position adjustment
Horizontal Shift 0.00 inch
0.0 mm
-1.00 to 1.00 inch
-25.4 to 25.4 mm
Horizontal printing location adjustment
Vertical Image Shift 000 dots -120 to 120 dots Adjust the o set value in vertical when
mapping data on a RAM.
Media Sensor See Through See Through
Reect
None
Label sensor selection
Small Media
Adjustment
O On
O
Setting for small labels
Small Media Length 1.00 inch
25.4 mm
0.25 to 1.00 inch
6.40 to 25.4 mm
Setting length of small label media
System Setup
Sensor Level
1.5 V 0.0 V to 3.3 V Setting the threshold of the sensor
Paper End Level
2.80 V 0.01 V to 3.00 V Sets the paper end level.
Error Reporting On Printing
On Printing
Immediate
Setting for error report.
Buzzer Select On On
O
Setting buzzer sounding conditions
Metric/Inch Inch Inch
mm
Setting the units used
Max Media Length 10.00 inch
254.0 mm
1.00 to 50.00 inch
25. 4 to 1270.0 mm
Setting the maximum label length
Settings Lock O On
O
When on, prevents software commands
from changing the values set by the VuePrint
menu
Keyboard Lock O On
O
Prevents the control panel from aecting
the printer’s conguration. (User “lock-out”)
Media Power Up
O On
O
Selects whether or not to initiate media
measurement when the power in ON.
CI Lock O On
O
Activates/deactivates the CI command.
Mode Settings
[Zebra® Emulation]