3-6. Adjustments
3-43 CLP-621 & CLP-631 3-43 CLP-621 & CLP-631
When adjustment is successful, “Finished DAC XXX” is displayed. When adjustment is successful, “Finished DAC XXX” is displayed.
*The value “143” is one of samples.
9. Press any key on the control panel to store the adjusted value.
Proceed to step 10 to perform reflective sensor adjustment.
[When adjustment failed]
When adjustment failed, “Cannot Setup” is displayed.
1) Press any key on the control panel to return to the screen in step 4.
2) Check the mechanical sensor positions, current Media sensor menu setting, label
paper, etc. and try again.
[Reflective sensor sensitivity adjustment, Media: Tag]
10. Press the [PAUSE] key to select the reflective sensor menu.
“Ini Refl Sensor” screen will appear.
[PAUSE] key
11. Press the [FEED] key to enter the reflective sensor menu.