2-5. Power Supply
CLP-621 & CLP-631 2-58
2-5-2. Block A (Noise filter circuit and rush current preventing circuit)
The filter circuit consists of the power switch (SW1) the fuse (F1), the X capacitors (C1, C2), the Y
capacitors (C3, C4), the common mode choke coils (L1 and L2), the varistor (Z1), and the
thermistor (R1).
This circuit eliminates switching noise from the power supply to the main power line. Also, it
eliminates noise from the main power line to the power supply to protect the power supply circuit.
The thermistor R1 suppresses the rush current to the power supply circuit at power on. In
continuous operation, the resistance of R1 is reduced as it is heated, reducing the power loss by
R1.
2-5-3. Block B (Current smoothing circuit)
This block consists of the bridge rectifier DS1, the smoothing capacitors C5-1 and C5-2, and
resistors R8 and R10.
<For 120V type>
Half-wave rectification is performed by the bridge rectifier DS1 and the capacitor C5-1 and also by
the bridge rectifier DS1 and the capacitor C5-2. Thus, the DC voltage across R8 and R9 (output of
this circuit) becomes approx. 2.8-time of the AC input voltage. (It will be approx. 320V DC if the
input voltage is 115V AC.) This DC voltage is supplied to the next converter and driver circuit.
<For 200-240V type>
Full-wave rectification is performed by the bridge rectifier DS1 and the capacitors C5-1 and C5-2.
The DC output of this circuit will be approx. 1.4-time of the AC input voltage. (It will be approx.
320V DC if the input voltage is 230V AC.) This DC voltage is supplied to the next converter and
driver circuit.
The choke coil L3 suppresses high frequency waves to meet the regulations against high
frequency waves.
2-5-4. Block C (Converter and driver circuit)
(1) Converter circuit
The converter circuit operates with conducting-angle-controlled reverse method with frequency
fixed. The rectified and smoothed voltage (e.g. 320V DC) is converted by the switching
transformer T1 and then supplied to the secondary circuit.
When Q1 is turned ON, 320V DC is applied to the primary winding N1 of T1. At this time, the
voltage is induced in the secondary windings N3 and N4 and energy is charged in T1 since the
energy flow to the secondary output circuit is blocked by the diodes DS2 and DS3.
When Q1 is turned OFF, the energy polarity is reversed and the energy charged in the
secondary windings N3 and N4 is discharged to the secondary output circuit through DS2 and
DS3. Above operation is repeated and the energy is continuously fed to the secondary output
circuit.

Other manuals for Citizen CLP-621

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citizen CLP-621 and is the answer not in the manual?

Citizen CLP-621 Specifications

General IconGeneral
USB portNo
RS-232 interfaceYes
Optional connectivityEthernet
USB 1.1 ports quantity1
USB 2.0 ports quantity0
Connectivity technologyWired
Flash memory2 MB
CertificationUL, C-UL, FCC class A, CCC, CE Marking
Internal memory8 MB
Number of fonts2
Built-in barcodesPDF417, UPC-A, UPC-E
Built-in processor32 Bit RISC
Mean cycles between failures (MCBF)1000
Power consumption2400 mA
Power requirements100 - 240V, 50 / 60Hz
Compatible operating systemsWindows 2000, XP, Vista
Core diameter25.4 mm
Ribbon length360 m
Media thickness0.0635 - 0.254 mm
Maximum label length812 m
Maximum roll diameter127 mm
Supported paper width19.5 - 118 mm
Weight and Dimensions IconWeight and Dimensions
Depth114 mm
Width91 mm
Height104 mm

Related product manuals