EasyManuals Logo

Citrix ADC MPX User Manual

Citrix ADC MPX
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Citrix ADC MPX
1 sh raid
2 <!--NeedCopy-->
Output:
1 RAID1 status: READY
2 Drive:
3 1 ONLINE
4 2 ONLINE
5 Done
6 <!--NeedCopy-->
If both the SSDs’ show ONLINE and the RAID status shows READY, no action is required.
In the following table, the values in the first column show the drive number on the back panel of the
appliance. The drive number in the other columns refers to the number that must be used in the
command or as it appears in the output of the CLI and shell.
Chassis CLI command Shell command Shell command Shell command
Slot in chassis sh raid atacontrol
status ar0
atacontrol
detach /
atacontrol
attach
atacontrol
addspare ar0
SSD 1 drive 1 drive 0 ata2 ad4
SSD 2 drive 2 drive 1 ata3 ad6
The following output indicates SSD 2 has failed and must be replaced.
Command:
1 sh raid
2 <!--NeedCopy-->
Output:
1 RAID1 status: DEGRADED
2 Drive:
3 1 ONLINE
4 2 MISSING
5 Done
6 <!--NeedCopy-->
© 19992023 Cloud Soware Group, Inc. All rights reserved. 112

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX and is the answer not in the manual?

Citrix ADC MPX Specifications

General IconGeneral
CategoryNetwork Hardware
TypeApplication Delivery Controller
Virtualization SupportYes
Power SupplyRedundant power supplies
High AvailabilityYes
Product SeriesCitrix ADC
ModelMPX
PortsVaries by model
RedundancyYes
Protocols SupportedHTTP, HTTPS, TCP, SSL, DNS
Security FeaturesDDoS protection
Operating SystemCitrix ADC

Related product manuals