3. Add the FRU drive to the RAID array.
4. Verify that the replacement drive is recognized.
5. Start the rebuild process.
6. Monitor the rebuild process.
7. Verify that the rebuild is successful.
8. Exit the bash shell and verify from the Citrix ADC CLI.
Example when SSD 2 fails
In the following example, SSD 2/drive 1/ata3 has failed.
1. Detach a failed drive.
1 root@ns# atacontrol detach ata3
2 <!--NeedCopy-->
2. Physically, remove SSD 2/drive 1 and replace it with a new FRU drive in slot 2.
3. Attach the FRU drive.
1 root@ns# atacontrol attach ata3
2 <!--NeedCopy-->
4. Add the FRU drive to the RAID array.
1 root@ns# atacontrol addspare ar0 ad6
2 <!--NeedCopy-->
5. Verify that the replacement drive is recognized.
1 root@ns# atacontrol status ar0
2 <!--NeedCopy-->
Output:
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 ONLINE
4 1 ad6 SPARE
5 <!--NeedCopy-->
6. Start the rebuild process.
© 19992023 Cloud Soware Group, Inc. All rights reserved. 114

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX and is the answer not in the manual?

Citrix ADC MPX Specifications

General IconGeneral
CategoryNetwork Hardware
TypeApplication Delivery Controller
Virtualization SupportYes
Power SupplyRedundant power supplies
High AvailabilityYes
Product SeriesCitrix ADC
ModelMPX
PortsVaries by model
RedundancyYes
Protocols SupportedHTTP, HTTPS, TCP, SSL, DNS
Security FeaturesDDoS protection
Operating SystemCitrix ADC

Related product manuals