OEM Softener System Setup
In OEM Softener System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and speci es other
operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows:
Cycle Options Units Lower/Upper Limit
Backwash Minutes 1 to 120
Rinse (fast) Minutes 1 to 120
dn Brine (combination of brining and slow rinse) Minutes 1 to 180
up Brine (combination of brining and slow rinse) Minutes 1 to 180
Fill for 1”, 1.25” and 1.5” kg 0.05 to 90.00
Fill for WS2 valves or WS1.5 set to MIN Minutes 0.1 to 99.0
Service Minutes 1 to 480
Since no time is associated with the END cycle, the END cycle will not appear in the OEM Softener System Setup sequence.
STEP 1S
Step 1S – Press NEXT and simultaneously for 3 seconds and release. If screen in Step 2S does not
appear in 5 seconds the lock on the valve is activated. To unlock press , NEXT, , and SET CLOCK
in sequence, then press NEXT and simultaneously for 3 seconds and release.
STEP 2S
STEP 3S
Step 2S – Choose SOFTENING using or . Press NEXT to go to Step 3S. Press REGEN to exit
OEM Softener System Setup.
Step 3S – Select the time for the rst cycle (which in this example is BACKWASH) using or .
Press NEXT to go to Step 4S. Press REGEN to return to previous step.
STEP 4S
STEP 5S
Step 4S – Select the time for the second cycle (which in this example is dn BRINE) using or .
Press NEXT to go to Step 5S. Press REGEN to return to previous step.
NOTE: The display will ash between cycle number and time, and brine direction (dn).
Step 5S – Select the time for the third cycle (which in this example is RINSE) using or . Press
NEXT to go to Step 6S. Press REGEN to return to previous step.
STEP 6S
Step 6S – Select the kg or MIN for the fourth cycle (which in this example is FILL) using or .
When 2.0 is selected in Step 2CS, or MIN is selected in Step 12CS, FILL is in minutes. WS2 valves are
shipped from the factory with a re ll ow contol of 2.2 gpm (8.3 lpm). Press NEXT to go to Step 7S.
Press REGEN to return to previous step.