12.0 FACTORY PROGRAM
To enter press Next and down for 5 seconds
Screen Entered Value Explanation
Softening Softening Valve
1 Backwash 25 4
30 4
50 6
75 6
100 8
120 8
150 8
250 10
350 10
500 10
750 10
Backwash time against resin
volumes
2 Brine 25 40
30 60
50 60
75 60
100 80
120 80
150 80
250 100
350 120
500 120
750 120
Brine draw slow rinse against
resin volumes
3 Backwash 4 Second Backwash time
4 Rinse 25 4
30 4
50 6
75 6
100 8
120 8
150 8
250 10
350 10
500 10
750 10
Fast Rinse time against resin
volumes
5 Fill 25 3.5
30 4.2
50 7
75 10.5
100 14
120 16.8
150 21 or 6 for WS2