17.1 LEVEL OF BATTERY ELECTROLYTE
Check the level of electrolyte. If the level is low, replenish with distilled water.
When checking the lever of electrolyte, inspect the float condition through the
electrolyte cover from outside. If the float isn’t seen, replenish with distilled water.
17.2 HOW TO READ THE GRAVIMETER
• Specific gravity for charging : 1.280 (20°C)
• Specific gravity for discharging : 1.180 (20°C)
If the specific gravity is under 1.180 (20°C), perform the equal charging.
!
17.
LEVEL OF BATTERY ELECTROLYTE AND READING GRAVIMETER
Appropriate
level
Thermometer
Gravi
meter
(Replenish with distilled water.)
Appropriate
(Float is seen.)
Lack
(Float isn’t seen.)