3 – 3
d When starting to fill up distilled water,
loosen the pinch cork and push the
center of distilled water container with
your hand several times to make
distilled water come out by syphon
action.
e When the red float goes up and you
see the white line, close the pinch
cork immediately.
f After filling up distilled water, close the
distilled water container and completely
close the electrolyte cover.
g Clean up the top of battery with wet
towel, etc.
22.3 MEASURING SPECIFIC GRAVITY
Measure the specific gravity and
temperature of all cells. If the specific
gravity converted into 20°… is almost the
same with the specific gravity of whole cell,
it is good. If there is a cell whose specific
gravity is 0.05 or lower than the average
value, it is abnormal. At this time, make
contact your local dealer. For how to see
the specific gravity, refer to <level of
battery electrolyte and reading gravimeter>.