Tranquility
®
Digital (DXM2)—Troubleshooting Guide
Rev.: 10 March, 2015
2
Geothermal Heating and Cooling
Troubleshooting ClimateMaster Tranquility
®
Digital Packaged Heat Pumps is quite straightforward.
Most problems relate to water ow. Either there isn’t enough water ow or the entering water temperature is improperly
supplied. Most service problems can be addressed without refrigerant gauges. In fact, installing gauges on packaged heat
pumps can do more harm than good because packaged heat pumps contain less refrigerant compared to split systems.
The rst thing to do is always perform a water side check (Heat of Extraction for Heating or Heat of Rejection for Cooling) to
determine if the unit is operating properly.
Set up and diagnostics are made easier using the communicating thermostat (ATC32) or the communicating service tool
(ACDU02). You must have ATC32 or ACDU02 to properly work on ClimateMaster Tranquility
®
Digital units that use the DXM2
control board.
Follow the ow chart on the following pages to help diagnose and solve your issue.