MAN.234 Rev.6 ENG - Use and maintenance manual S19HD page 41 of 126
If full lithium version (*optional), before
any work start, check the battery charge
level. It is necessary to have at least 75% of
battery charge, otherwise it is advisable to
charge them before working.
4.4.1 Placement on the work area
1. Start the machine engine through the engine
ignition key supplied (Picture 4).
2. Identify the working area which is nearest to
the working place.
3. Make sure the soil bears the load of the out-
riggers and check that there are no man-
holes, floors or other soft structures in the
contact point of every outriggers plate with
the ground.
If these conditions are not met, it is strict-
ly forbidden to use the MEWP.
4. Place the MEWP on the chosen area, travel-
ling by radio control (par. 4.3.3.1).
C.M.C. obligates to use the remote travel
controls, in order to perform the travel
operations in complete safety.
5. Mark the work area with proper signals
(white-red tape, white-red chains, pins, etc.).
4.4.2 MEWP stabilization
The MEWP has two different stabilization areas, ac-
cording to the different combinations of possible out-
rigger placement. An electronic locking system
uniquely ensures the chosen working configuration.
The movement of the outriggers must be
possible only when the booms are resting
on their supports. This condition causes the
stabilization consent light 8 (Picture 4) to
light up on the control stations.
6. Pull out the locking pin of the outriggers P
(Picture8) from the hole;