Chapter 3: Service & maintenance
22 Troubleshooting
9002
9003
BDU temperature above
warning level
BDU temperature above
critical level
On temperature warnings try to
provide sufficient ventilation to
the terminal (opening lockers,
check fans, etc.).
On detection of critical
temperatures the system will halt
completely after 30 seconds.
Manual restart is required after
cooling has been provided.
9004
9005
9006
9007
9008
9009
900A
BDU Internal voltage
errors.
Contact your service partner.
900C
900D
BDU PSU temperature
above warning level
BDU PSU temperature
above critical level
(System will enter a
protection state)
On temperature warnings try to
provide sufficient ventilation to
the terminal (opening lockers,
check fans, etc.).
On detection of critical
temperatures the system will halt
completely after 30 seconds.
Manual restart is required after
cooling has been provided.
9101 BDU SIM card reader
empty. No service
Insert a valid SIM card.
9102 BDU cannot connect to
the Iridium modem
Restart the terminal (see below).
Contact your service partner.
9104 Data connection not
possible
Contact Iridium service provider.