EasyManuals Logo

Codan 9323 Service Manual

Codan 9323
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
Adjustments
7-10 HF SSB Transceiver 9323/9360/9390/9780 Technical Service Manual
VCO checks and adjustments
VCO1 check
108-04962
There is no adjustment for VCO1, which is located on the Rx/Exciter PCB. To
check VCO1 is operating correctly perform the following in Test mode.
q Select Test 1.
q Ensure the screening can is over VCO1 and Mixer 1 for the test.
q Connect a DC voltmeter to TP1 and check for a reading between 9.0-11.5 V.
The frequency at TP4 should measure 60 MHz ±100 Hz.
q Select Test 2.
q Check the voltage at TP1 reads 19-25 V. The frequency at TP4 should
measure 75 MHz ±100 Hz.
q Select Test 3.
q Check the voltage at TP1 reads 2-4 V. The frequency at TP4 should measure
45.25 MHz ±100 Hz.
VCO2 check
108-04962 and 08-05322
VCO2 is located on the Rx/Exciter PCB and can be checked in Test mode. The
test point and measurement results for 108-05322 are given in brackets.
q Select Test 1.
q Connect a DC voltmeter to TP5 (TP9) and check for a reading between
7.8-8.2 V. The frequency at TP8 should measure 44.5445 MHz ±100 Hz
(44.5455 MHz ±100 Hz).
q Select Test 2.
q Check the voltage at TP5 (TP9) reads between 11-17 V. The frequency at
TP8 should measure 44.5485 MHz ±100 Hz (44.5495 MHz ±100 Hz).
q Select Test 3.
q Check the voltage at TP5 (TP9) reads between 2-5 V. The frequency at TP8
should measure 44.5405 MHz ±100 Hz (44.54145 MHz ±100 Hz).
q If the measurements are not within the stated limits, adjust VCO2 (see page
7-11, VCO2 adjust).