Adjustments
7-16 HF SSB Transceiver 9323/9360/9390/9780 Technical Service Manual
©
In this Test 5, VCO1 and VCO2 are set to 44.544 MHz allowing the receive
frequency to equal the 455 kHz IF frequency. This allows the spectrum
analyser and tracking generator to be used to align the BPF at a frequency of
455 kHz.
q Remove the shorting link to B–E and return it to its parking position (ground
pins of link E–E).