EasyManua.ls Logo

Codan 9780 - Receiver Performance Verification Tests

Codan 9780
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjustments
7-28 HF SSB Transceiver 9323/9360/9390/9780 Technical Service Manual
Receiver performance checks
Sensitivity and (S+N)/N ratio
q Connect an AC voltmeter across the audio output (loudspeaker).
q Select RF gain on test channel 3.
q Set the signal generator frequency 1 kHz above the SCF of the selected
channel (1 kHz below for LSB).
q Connect the output, set to 0.15 µV PD (123 dBm), to the antenna
socket J1.
q Adjust the volume control for a suitable near full scale dB reading on the
AC voltmeter. Take note of the reading.
q Switch off or adjust the signal generator output to a frequency outside the
receiver band-pass. Check that the audio output drops by at least 10 dB.
q Repeat the above test with the RF gain off (test channel 20 for 2 to
26.5 MHz PA [1 08-04963] or test channel 29 for 2.25 to 30 MHz PA
[1 08-05237]) and with the signal generator output set to 0.4 µV PD
(-115 dBm).
q Check the audio output drops by at least 10 dB when the signal generator is
switched off or tuned out of the band-pass.
AGC check
q Set up the equipment as for the sensitivity test (see page 7-28, Sensitivity
and (S+N)/N ratio) but with the signal generator output set to 50 mV PD
(-13 dBm).
q Adjust the volume control for a suitable, near full-scale dB reading on the
AC voltmeter.
q Take note of the reading.
q Reduce the signal generator output until the receiver output drops by 6 dB.
The signal generator level should be less than 2.5 µV PD (99 dBm).