EasyManua.ls Logo

Codan 9780 - Noise Limiter Operation

Codan 9780
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjustments
7-30 HF SSB Transceiver 9323/9360/9390/9780 Technical Service Manual
Noise limiter operation
q Check the RF gain is off (test channel 20 for 2 to 26.5 MHz PA
[1 08-04963] or test channel 29 for 2.25 to 30 MHz PA [1 08-05237]).
q Set the signal generator frequency 1 kHz above the SCF of the selected
channel (1 kHz below for LSB).
q Connect the output via a tee piece to the antenna socket J1.
q Set the signal generator to 0.4 µV PD.
q Connect a BNC to a two-terminal adaptor. Connect this to the other end of
the tee piece.
q Connect the output of a square-wave generator to the adaptor via a 100 pF
capacitor.
q Set the square-wave generator frequency to a 100 Hz and the output to
5 V PP.
When the noise limiter is on, the signal produced by the signal generator
should be clearly heard over the interfering signal from the square-wave
generator.
q Switch the noise limiter off by shorting A–E on noise limiter test point
TP202 located on the Rx/Exciter PCB [1 08-04962 and 08-05322].
The noise from the square-wave generator should swamp the wanted signal
from the signal generator. This test will verify the noise limiter is
functioning correctly.

Table of Contents

Related product manuals